FP-78-IN2

 

Features:

• Passes PS 700MHz and PS 800MHz (769-775MHz, 799-816MHz, 851-861MHz)

• Reject 700 Upper C, LTE Band 14 downlink interference to Public Safety In-Building network

• Reject ESMR, 850MHz downlink interference to Public Safety In-Building network

• Improve Public Safety Equipment output to protect 700 Upper C, LTE Band 14 uplink

• Improve Public Safety Equipment output to protect ESMR, 850MHz uplink

Description

Electrical Specifications:

 

 Product ModelFP-78-IN2
 Pass Band (MHz) 769-775, 799-816, 851-861
 Insertion Loss (dB)

4.0 Max

5.0 (Over Temperature)

 Rejection (dB)

55dBc @ 0-767MHz

30dBc @ 777-797MHz

30dBc @ 818-849MHz

45dBc @863-2200MHz

 Return Loss (dB)≥ 18
 Input Power Per Port, max (W)50
 Impedance (Ohm)50

 

Mechanical Specifications:

 

 Dimension Diameter, Height   (in)

8.9 x 9.5

(without connector)

  Weight w/o  Mounting Kit (lb/kg)

4.0

 Connector TypeN-Female

 

 

Environmental Specifications:

 

ApplicationIndoor
 Operating Temperature-40°C to +167°C
 EnvironmentIP67
 Relative HumidityUp to 100%
 RoHSCompliant

 

 

Outline Drawing:

 
 

 

 
 