CP-AMS-V2-MCU (Main Control Unit)

 

IX-MJN-V5PRT2 (Indoor Omni Addressable Antenna, Ceiling Mount, V Pol, 360°, 698-960/1710-2700MHz, 2/5dBi, N-female, with RFID Tag integrated)

IXL-MJN-H4URT2 (Omni Antenna, 698-2700MHz w/RFID Tag)

IWH-MUN-V8RT2 (Indoor Directional Addressable Antenna, Wall Mount, 698-4000MHz, V Pol, 80°, 5.0/8.5dBi, with tag pre-installed internally)

IXL-EYN-H2PRT2 (Indoor Omni-directional Ceiling Mounted Antenna, H Pol, 360°, 132-174/380-570/698-960MHz, 0.5/1.5/4.0dBi, N-female, Rodome and Cable: UL-94-V0, with RFID Tag integrated)

IXL-YJN-H4PURT2 (Omni Antenna, Ceil Mount, 380-2700MHz, 4dBi, UL-94-V0, N-Female with RFID tag)

 

Features:

 

• Monitor In-building status in real time for all passive components, antenna coax, and service antennas
• Report overall status through dry contact alarming – login to identify alarms from individual antenna paths
• Supports Monitoring VHF, UHF/T band, 700/800MHz systems
• Supports up to 25dB cable loss for Antennas with RFID-Tags V1
• Supports up to 28dB cable loss for Antennas with RFID-Tags V2
• Improved scanning speed and mechanism
• Built-in Web based user interface
• Supports Form C dry contact alarms
• MCU is housed in a NEMA 4 enclosure
• System status LEDs supported
• Low Power Consumption
• FCC: PX8CP-AMS-V2-MCU
• UL-62368-1: SGSNA/25/GZ/00042

 

Datasheet: Download

Description

Master Control Unit:

 

 Pass Band (MHz) 902 - 928 (Default: 910)
 Input Frequency Range (MHz)136 - 869
 Insertion Loss (dB)0.5
 Output Power per Antenna (dBm)<10
 Power Consuption (W)Avg. <6 (Peak: 0.6A, 28.8W)
 Power Accuracy (dB)+/- 2dB
 Receiver Sensitivity (dBm)- 70
 Max Cable Loss Supported (dB)25
 Max Numbers of Antennas (Tags) Supported50
 Passive Components Supported

Wilkinson Splitters, Directional Couplers

(Tappers or High Reactive Splitters are NOT supported)

 

 Master Control Unit Dry Contact Alarms:

 

 Dry contact alarm 1Unit Fail Alarm
 Dry contact alarm 2Antenna Fail Alarm (Overall)

 

 Master Control Unit Mechanical Specifications:

 

 Dimension Diameter, Height (in)

12.5 x 8.9 x 5.2

 Weight (lb)15.5
 Environmental ClassNEMA 4
 ApplicationOutdoor / Indoor
 Operating Temperature (°F)-4 to +131
 Operating Humidity<= 95%
 Enclosure CoolingConvection
 Power Supply

VAC 100-240

VDC -48

 RF InputN-Female
 RF OutputN-Female
 RoHSCompliant

 

 Tag Specifications:

 

 Frequency Band (MHz)

902 - 928

 Sensitivity (dBm)-21
 Ingress protectionIP30
 Operating Temperature (°F)-4 to +131
 Operating Humidity<= 95%

This website uses cookies and similar technologies. By continuing to browse the site, you agreeing to our use of cookies. Read our Privacy Policy.