CP-AMS-V2-MCU (Main Control Unit)

 

IXD-360H04NM40-RT (Indoor low profile antenna, 380-2700MHz, w/ pre-installed internal tag)
IXD-360H04NT53-RT (Indoor low profile antenna, 698-2700MHz, w/ pre-installed internal tag)
IXD-360V05NT40-RT (Indoor wide band antenna, 689-2700MHz, w/ pre-installed internal tag)
IWH-080V08NZ-RT (Indoor directional wall mounted antenna, 698-4000MHz, w/ pre-installed internal tag)
IXL-MJN-H4URT (Indoor wide band antenna, 698-2700MHz, w/ pre-installed internal tag)

 

Features:

 

• Monitor In-building status in real time for all passive components, antenna coax, and service antennas
• Report overall status through dry contact alarming – login to identify alarms from individual antenna paths
• Supports Monitoring VHF, UHF/T band, 700/800MHz systems
• Supports up to 25dB cable loss for Antennas with RFID-Tags V1
• Supports up to 28dB cable loss for Antennas with RFID-Tags V2
• Improved scanning speed and mechanism
• Built-in Web based user interface
• Supports Form C dry contact alarms
• MCU is housed in a NEMA 4 enclosure
• System status LEDs supported
• Low Power Consumption
• FCC: PX8CP-AMS-V2-MCU
• UL-62368-1: SGSNA/25/GZ/00042

 

Datasheet: Download

Description

Master Control Unit:

 

 Pass Band (MHz) 902 - 928 (Default: 910)
 Input Frequency Range (MHz)136 - 869
 Insertion Loss (dB)0.5
 Output Power per Antenna (dBm)<10
 Power Consuption (W)Avg. <6 (Peak: 0.6A, 28.8W)
 Power Accuracy (dB)+/- 2dB
 Receiver Sensitivity (dBm)- 70
 Max Cable Loss Supported (dB)25
 Max Numbers of Antennas Supported50

 

 Master Control Unit Dry Contact Alarms:

 

 Dry contact alarm 1Unit Fail Alarm
 Dry contact alarm 2Antenna Fail Alarm (Overall)

 

 Master Control Unit Mechanical Specifications:

 

 Dimension Diameter, Height (in)

12.5 x 8.9 x 5.2

 Weight (lb)15.5
 Environmental ClassNEMA 4
 ApplicationOutdoor / Indoor
 Operating Temperature (°F)-4 to +131
 Operating Humidity<= 95%
 Enclosure CoolingConvection
 Power Supply

VAC 100-240

VDC -48

 RF InputN-Female
 RF OutputN-Female
 RoHSCompliant

 

 Tag Specifications:

 

 Frequency Band (MHz)

902 - 928

 Sensitivity (dBm)-21
 Ingress protectionIP30
 Operating Temperature (°F)-4 to +131
 Operating Humidity<= 95%